OEM Boiler Bodies for Solid Fuel Boilers

U22 C

U22C

Cast-iron sectional boiler body suitable for burning of solid fuels (coke, coal) for rated output 11 - 58 kW.

U22C Boiler Body
Number of Sectionspcs 2345678910
Rated outputkW11.717.723.329.134.940.746.552.358.1
Dimensions – height × widthmm889x440
Dimensions – depthmm5716687648609561052114812441340
Heating water connection fitting 2"
Weightkg159192224256287317349379411
Water volumel26.131.536.240.945.650.35559.764.4
Maximal operational water pressureMPa0.4

U22D

Cast-iron sectional boiler body suitable for burning of wood for rated output 22 - 53 kW.

U22D Boiler Body
Number of Sectionspcs 45678910
Rated outputkW20253035404549
Dimensions – height × widthmm889x440
Dimensions – depthmm7648609561052114812441340
Heating water connection fitting 2"
Weightkg219246278310342372404
Water volumel35.238.943.648.35357.762.4
Maximal operational water pressureMPa0.4

U 26

Cast-iron sectional boiler body suitable for solid fuel boilers (coke, hard coal, wood) in the range of heat outputs: coke from 15 to 63 kW, hard coal from 11 to 58 kW, wood pieces from 8 to 46 kW.

U26 Boiler Body
Number of Sectionspcs 345678910
Rated output (coke)kW1522.53037.543.5505663
Rated output (hard coal)kW1116.522.53139.545.551.558
Rated output (wood)kW815.752028.25333540.546
Dimensions – height × widthmm1018x442
Dimensions – depthmm5937048159261037114812591370
Heating water connection fitting 2"
Weightkg192236280323367410454498
Water volumel27.633.33944.750.456.161.867.5
Maximal operational water pressureMPa0.4

U24

Cast-iron sectional boiler body suitable for ecological boilers for solid fuels (soft coal, hard coal, coke) in the range of heat outputs: coke from 17 to 74 kW, hard coal from 17 to 68 kW, soft coal from 11 to 55 kW. The boilers comply with the emission class 3 according to EN 303-5.

U 24 Boiler Body
Number of Sectionspcs 345678910
Rated output (soft coal)kW1119253137434955
Rated output (hard coal)kW1125324246536068
Rated output (coke)kW1725374652586674
Dimensions – height × widthmm1053x530
Dimensions – depthmm40051162273384495510661177
Heating water connection fitting 6.4"
Weightkg262312362412462512562612
Water volumel39.549.359.168.978.788.598107.8
Maximal operational water pressureMPa0.4